General service life of gas regulator

May 15, 2019

Leave a message

Since the pressure regulator is the main equipment in the pressure regulating facility, the maintenance of the gas pressure regulator is a key management link to ensure safe gas supply. Once the regulator fails, the unregulated, higher pressure gas is delivered directly downstream, with unimaginable consequences. Therefore, the attention of each gas management unit on the maintenance and service life of the gas pressure regulator has become increasingly prominent.


1 It is difficult to uniformly specify the service life of the regulator

For the service life of gas pressure regulators, not only in China, even in developed countries, there is no clear service life for a variety of complicated regulators. Under normal circumstances, the manufacturer has a certain description of the maintenance of the regulator in the instruction manual, but the life of the whole equipment is never mentioned. This is not the intention of the manufacturer to avoid the problem, but the following factors:

1 At present, domestic regulator products do not have a non-removable assembly structure for the whole equipment or equipment core components, and most of the faults can be solved by maintenance.

2 For existing pressure regulators, there are no relevant standards, regulations, and literature regulations. Which components in the structure can represent the life of the overall equipment without any fatigue limit requirements and fatigue test requirements.

3 There are many types of regulators and different parts and materials.

Therefore, it is difficult to uniformly define the life of the gas pressure regulator.


2 Factors that cause damage to the gas pressure regulator

There are many factors affecting the normal use of gas pressure regulators, which can be summarized into the following three types.


1 Gas temperament effects

a. If the gas contains a certain amount of substances such as S02, H2S, aromatic hydrocarbons, tar, etc., it is easy to cause damage to the rubber parts.

b. If the gas contains a certain amount of substances such as S02, H2S, H2O, O2, etc., it will cause corrosion damage of copper, iron and other metal parts.

e. If the gas contains a certain amount of particulate dust, it will affect the sliding fit of the metal parts after prolonged use, resulting in equipment failure and malfunction.

d. If the gas contains a certain amount of particulate dust, high-speed dust may cause damage to the casing and other components when the flow rate is large. This damage due to wear or impact is more common in the door station.

e. If the gas contains a certain amount of substances that are prone to phase change at normal temperature, such as elemental sulfur, naphthalene, anthracene, light oil, etc., it will produce effusion and surface grains on the stem, cavity, diaphragm, etc. Adhesion, affecting the normal use of the regulator.


2 The impact of actual use conditions

a. If the pressure difference between the inlet and outlet is too large and the flow rate is large, cavitation damage will be caused to the metal parts, especially the casing.

b. The ambient temperature is too high or too low. In some cases, when the pressure is greatly reduced and the heating is poor, the temperature of the medium is too low, which will cause damage to the film and other rubber parts.

c. If the equipment is not properly selected, the difference between the actual passing capacity range and the rated passing capacity of the equipment is too large, which may cause damage to the moving parts of the equipment in whole or in part.


3 The impact of the device itself

a. Defects in the structure of the device itself.

b. Material defects in the parts used in the equipment.

Among the above factors affecting the normal use of gas pressure regulators, some may cause local damage that can be repaired, while others may cause permanent damage to the overall equipment.


3 Factors related to equipment replacement

In the development history of China's gas pressure regulators, there are several major update and elimination processes. The first is due to structural considerations, such as the Renault-type regulator, the main reason for the update is because of its complex structure, difficult maintenance, and large footprint. Secondly, due to safety considerations, equipment with external exhaust function, such as piston regulators, is used. This is the replacement of two large-scale regulators in the gas range of the local gas companies. Gas companies around the country also have their own unique equipment management mode and the way to replace equipment, depending on the specific circumstances.


4 life of the regulator

The specific service life of the regulator is related to the specific use environment and cannot be generalized.


Send Inquiry