There are many factors affecting the normal use of gas pressure regulators, which can be summarized into the following three types.
1 Gas temperament effects
a. If the gas contains a certain amount of substances such as S02, H2S, aromatic hydrocarbons, tar, etc., it is easy to cause damage to the rubber parts.
b. If the gas contains a certain amount of substances such as S02, H2S, H2O, O2, etc., it will cause corrosion damage of copper, iron and other metal parts.
e. If the gas contains a certain amount of particulate dust, it will affect the sliding fit of the metal parts after prolonged use, resulting in equipment failure and malfunction.
d. If the gas contains a certain amount of particulate dust, high-speed dust may cause damage to the casing and other components when the flow rate is large. This damage due to wear or impact is more common in the door station.
e. If the gas contains a certain amount of substances that are prone to phase change at normal temperature, such as elemental sulfur, naphthalene, anthracene, light oil, etc., it will produce effusion and surface grains on the stem, cavity, diaphragm, etc. Adhesion, affecting the normal use of the regulator.

2 The impact of actual use conditions
a. If the pressure difference between the inlet and outlet is too large and the flow rate is large, cavitation damage will be caused to the metal parts, especially the casing.
b. The ambient temperature is too high or too low. In some cases, when the pressure is greatly reduced and the heating is poor, the temperature of the medium is too low, which will cause damage to the film and other rubber parts.
c. If the equipment is not properly selected, the difference between the actual passing capacity range and the rated passing capacity of the equipment is too large, which may cause damage to the moving parts of the equipment in whole or in part.
3 The impact of the device itself
a. Defects in the structure of the device itself.
b. Material defects in the parts used in the equipment.
Among the above factors affecting the normal use of gas pressure regulators, some may cause local damage that can be repaired, while others may cause permanent damage to the overall equipment.