The gas pressure reducing valve is a safety device for adjusting the gas pressure, and has the advantages of simple structure, stable pressure, light weight, convenient adjustment and installation. Today, I will give you a detailed analysis of the causes of gas leakage from gas pressure reducing valves and the treatment of gas leakage.
1, the cause
The upper and lower cover screws of the gas pressure reducing valve are not tightened. The rubber film inside the valve body is damaged. The air inlet seal is aging damaged.
2, the processing method
Tighten the upper and lower cover screws. Replace the rubber film. The rubber sealing ring at the connection between the gas pressure reducing valve and the cylinder plays the role of sealing and supplying air. After long-term use, it will wear and aging. Even when the cylinder is replaced, it will fall off by itself and cause a lot of running gas, causing serious accidents. Therefore, every time you replace the cylinder, when installing the pressure reducing valve, you should pay special attention to check whether the rubber sealing ring is intact, whether it is aging or wear, especially when installing, you must check the sealing ring for loss. If it has been aging or worn, it should be replaced in time, but it is not feasible to cut it with film, and a special sealing ring must be used.
3. The aging of the rubber film of the gas pressure reducing valve is a common cause of air leakage. It is understood that many users in order to use the bottom of the bottle to put the cylinder upside down, use hot water or fire to heat the gas cylinder, etc., so that the bottom of the gas bottle bottom residue into the pressure relief valve cavity, after a long time, the diaphragm is aging leakage. For safety reasons, these practices are not allowed.
In addition, if the fixed mother wire of the gas pressure reducing valve is loose, or the edge of the rubber film is crushed when the mother wire is tightened to fasten the upper and lower valve covers, air leakage may also occur. In particular, when the rubber film locking device is detached or the rubber film is broken, an explosion accident may occur due to high pressure gas supply.
4. The structure of the gas pressure reducing valve is relatively strict. It has been carefully assembled and assembled before leaving the factory and has been strictly tested before it leaves the factory. Therefore, the connecting screws and adjusting parts are not allowed to be disassembled or unscrewed by the user, so as to avoid reducing the gas. The sealing performance of the pressure valve and the pressure reduction and voltage regulation performance, it is also necessary to prevent the high-pressure direct air supply caused by the disassembly damage and cause a fire accident.
Gas leakage accidents occur frequently, which seriously threatens the safety of people's lives and property, so it is necessary to pay attention to the correct use of gas pressure reducing valves.