We know that when the liquefied petroleum gas comes out of the cylinder, the high-pressure gas first passes through the intake pipe to the decompression chamber. When the user turns off the switch of the gas appliance, as the liquefied petroleum gas entering the decompression chamber increases, the pressure rises. The rubber film pressed by the spring is pushed up, and part of the air existing in the upper air chamber is discharged from the valve body through the breathing hole.


In this way, the lever is forced to move upward, the valve port is closed by leverage, the passage of the liquefied petroleum gas inlet is cut off, and the pressure at the outlet of the pressure reducing valve is no longer raised. When the switch of the gas appliance is turned on, the liquefied petroleum gas flows out from the pressure reducing valve, so that the pressure in the decompression chamber is lowered, the rubber film is concave, the lever is moved downward, and the outside air enters the upper air chamber from the breathing hole, so that the valve cushion faces In the middle movement, the intake nozzle becomes larger, the intake air amount increases, and the pressure rises. This repeated adjustment process keeps the pressure in the decompression chamber constant, that is, regardless of whether the intake pressure is high or low, the outlet pressure is always stable, and thus until the pressure is reduced and the voltage is stabilized.